The air-water heat pump HR combines technology and design by 360 degrees
The air-water heat pump HR combines technology and design by 360 degrees. Apart from the property to integrate optimally into any living environment, the fan housing is located in the upper part of the device and thus avoiding annoying movements of air and the noise excretes up, which makes the device even quieter.
(For Monobloc and Split version) | KITA HR 10 - 12 - 14 | KITA HR 14 Cold | |
---|---|---|---|
Energy class | A +++ | ||
Electrical supply | Supply | V-Hz | 230-50 / 400-3-50 | 400-3-50 |
Noise level | Max sound pressure at 1 Meter | dB(A) | 38 | |
Compressor | Type | Scroll Inverter | |
Driver | Vapour Injection | ||
Fan Data | Type | Inverter BLDC | |
Fan diameter | mm | 630 | ||
Max speed rpm | 600 | ||
Heat exchanger | Distanza alette | mm | 2,5 | |
Heat exchanger | Type | Plate Exchanger | |
Material | Inox | ||
Refrigerant | Type | R410A | |
Refrigerant charge | kg | 6,5 | ||
Hydraulic circuit | Type pump | EC | |
Weight | Outdoor unit / Outdoor unit + indoor unit | kg | 230 Monobloc / 210 + 50 Split | |
Dimensions | Outdoor unit | mm | 880 Ø - 1800 h | |
Indoor unit | mm | H878,4 x L550 x P208 |
Compressor operating temperature | HR 10 | HR 12 | HR 14 | HR 14 Cold | |||
---|---|---|---|---|---|---|---|
Heating mode | Max power with full speed |
Air 12°C Water 35°C |
Thermal power (kW) | 10,50 | 12,60 | 14,55 | 14,55 |
COP | 5,50 | 5,40 | 5,30 | 5,30 | |||
Air 7°C Water 35°C |
Thermal power (kW) | 9,90 | 12,16 | 14,30 | 14,30 | ||
COP | 4,60 | 4,30 | 4,44 | 4,44 | |||
Air 2°C Water 35°C |
Thermal power (kW) | 8,81 | 10,79 | 13,09 | 14,00 | ||
COP | 4,07 | 3,91 | 3,82 | 3,78 | |||
Air -7°C Water 35°C |
Thermal power (kW) | 7,03 | 8,44 | 10,70 | 14,00 | ||
COP | 3,22 | 3,12 | 3,10 | 2,85 | |||
Air -15°C Water 35°C |
Thermal power (kW) | 5,70 | 6,60 | 9,10 | 13,30 | ||
COP | 2,93 | 2,82 | 2,80 | 2,70 | |||
Air -20°C |
Thermal power (kW) | 5,00 | 5,80 | 8,10 | 11,80 | ||
COP | 2,58 | 2,42 | 2,60 | 2,52 | |||
Air 2°C Water 55°C |
Thermal power (kW) | 8,19 | 9,81 | 11,76 | 14,00 | ||
COP | 2,75 | 2,59 | 3,10 | 2,49 | |||
Optimal Conditions |
Air 7°C Water 35°C |
Thermal power (kW) | 5,27 | 6,59 | 7,82 | 7,82 | |
COP | 5,26 | 5,22 | 5,21 | 5,21 | |||
Cooling mode | Max power with full speed |
Air 35°C Water 7°C |
Thermal power (kW) | 9,13 | 10,04 | 12,45 | 12,45 |
EER | 3,29 | 3,28 | 3,21 | 3,21 | |||
Air 35°C Water 18°C |
Thermal power (kW) | 11,86 | 13,06 | 16,23 | 16,23 | ||
EER | 4,95 | 4,76 | 4,67 | 4,67 |