The air and water heat pumps Kita S (S10) and Kita S Plus (S12) single and three phase are the smallest units of the Kita series. They can very well satisfy the needs of small residential users and those of low energy buildings with a very competitive price.
The Kita air-water heat pumps are equipped with the Twin Rotary inverter compressor, they heat, cool and produce domestic hot water in high temperature.
The heat pumps of the Kita series are available in both monobloc and split versions to meet your every need.
Compared to the standard heat pumps of this power range, which generally require integration from a boiler or electric heaters, Kita-S is designed to operate in monovalent mode, without any need for additions.
This therefore guarantees maximum energy savings and at the same time avoids the need to connect to a traditional fuel network
Energy class | A+++ | |
---|---|---|
Electrical supply | Supply | V-Hz | 230-50 / 400-3-50 |
Noise level | Max sound pressure at 1 Meter | dB(A) | 44 |
Compressor | Type | Twin rotary |
Driver | Inverter BLDC | |
Fan Data | Type | EC |
Fan diameter | mm | 710 | |
Max speed | rpm | 600 | |
Evaporator | Fin spacing | mm | 2,5 |
Heat exchanger | Type | Plate Exchanger |
Material | Inox | |
Refrigerant | Type | R410A |
Refrigerant charge | kg | 5 | |
Hydraulic circuit | Type pump | EC |
Weight | Outdoor unit / Outdoor unit + indoor unit | kg | 180 Monobloc / 160 + 50 Split |
Dimensioni | Outdoor unit | mm | H908 x L1406 x P550 |
Indoor unit | mm | H878.4 x L550 x P208 |
Operating conditions | Me | Compressor load | ||
---|---|---|---|---|
Med. | Max. | |||
Heating mode | Air 12 °C Water 35 °C |
Thermal power (kW) | 6,88 | 10,00 |
COP | 5,29 | 4,95 | ||
Air 7 °C Water 35 °C | Thermal power (kW) | 4,98 | 10,00 | |
COP | 5,16 | 4,25 | ||
Air 2 °C Water 35 °C |
Thermal power (kW) | 3,96 | 9,20 | |
COP | 4,44 | 3,56 | ||
Air -7 °C Water 35 °C |
Thermal power (kW) | 2,70 | 6,30 | |
COP | 3,30 | 2,80 | ||
Air -15 °C Water 35 °C |
Thermal power (kW) | 2,15 | 4,85 | |
COP | 2,86 | 2,71 | ||
Air 2 °C Water 35 °C |
Thermal power (kW) | 3,41 | 7,78 | |
COP | 2,77 | 2,12 | ||
Cooling mode | Air 35 °C Water 7 °C |
Cooling power (kW) | 3,83 | 7,40 |
EER | 3,27 | 2,92 | ||
Air 35 °C Water 18 °C |
Cooling power (kW) | 5,46 | 8,30 | |
EER | 4,70 | 4,20 |
Operating conditions | Me | Compressor load | ||
---|---|---|---|---|
Med. | Max. | |||
Heating mode | Air 12 °C Water 35 °C |
Thermal power (kW) | 7,60 | 11,80 |
COP | 5,27 | 4,35 | ||
Air 7 °C Water 35 °C | Thermal power (kW) | 6,19 | 12,00 | |
COP | 5,14 | 4,00 | ||
Air 2 °C Water 35 °C |
Thermal power (kW) | 4,91 | 11,40 | |
COP | 4,43 | 3,24 | ||
Air -7 °C Water 35 °C |
Thermal power (kW) | 3,35 | 9,00 | |
COP | 3,26 | 2,52 | ||
Air -15 °C Water 35 °C |
Thermal power (kW) | 2,80 | 6,00 | |
COP | 2,84 | 2,50 | ||
Air 2 °C Water 35 °C |
Thermal power (kW) | 4,27 | 9,60 | |
COP | 2,52 | 1,90 | ||
Cooling mode | Air 35 °C Water 7 °C |
Cooling power (kW) | 5,07 | 8,35 |
EER | 3,11 | 2,81 | ||
Air 35 °C Water 18 °C |
Cooling power (kW) | 7,25 | 8,70 | |
EER | 4,50 | 4,00 |