The Kita air-to-water heat pumps of the L series are ideal for heating, cooling and the production of domestic hot water in high temperature, even in situations of operation at particularly low temperatures.
They are equipped with a Scroll Inverter compressor with steam injection that guarantees operation in very difficult environmental situations that always allow excellent performance.
The heat pumps of the Kita L series are available in both monobloc and split versions to meet your every need.
L33 | L42 | L66 | L Cold | |||
Effizienzklasse | A+++ | |||||
Daten | Versorgung | V-Hz | 400-3-50 | |||
Schallbelastung | Maximaler Schalldruck auf 1 Meter | dB(A) | 52 | |||
Kompressor | Typ | Scroll Inverter | ||||
Driver | Vapour Injection | |||||
Ventilator | Typ | EC | ||||
Durchmesser Lüfter | mm | 800 (L33/L42) - 910 (L66/L Cold) | ||||
Geschwindigkeit | rpm | 600 (L33/L42) - 610 (L66/L Cold) | ||||
Gerippter Verdampfer |
Abstand der Rippen | mm | 2,5 | |||
Wärmetauscher | Typ | Plattentauscher | ||||
Material | Edelstahl | |||||
Kühlmittel | Typ | R410A | ||||
Menge Kühlmittel | kg | 8,5 (L33/L42) - 8 (L66/L Cold) | ||||
Hydraulischer Kreislauf | Typ pumpe | EC | ||||
Gewicht | Außeneinheit / Außeneinheit + Inneneinheit | kg | 280 Monoblock / 260 + 50 Split | |||
Maße | Außeneinheit | mm | H1257 x W1791 x D6451 | |||
Inneneinheit | mm | H878.4 x W550 x D208 |
Betriebsbedingungen | Kompressorlast | |||
---|---|---|---|---|
Med. | Max. | |||
Heizung | Luft 12 °C Wasser 35 °C |
Thermische Leistung (kW) | 16,50 | 27,10 |
COP | 5,74 | 4,64 | ||
Luft 7 °C Wasser 35 °C |
Thermische Leistung (kW) | 15,52 | 25,50 | |
COP | 5,34 | 4,31 | ||
Luft 2 °C Wasser 35 °C |
Thermische Leistung (kW) | 15,05 | 24,50 | |
COP | 4,52 | 3,85 | ||
Luft -7 °C Wasser 35 °C |
Thermische Leistung (kW) | 10,94 | 20,10 | |
COP | 3,40 | 3,25 | ||
Luft -15 °C Wasser 35 °C |
Thermische Leistung (kW) | 8,12 | 17,50 | |
COP | 2,78 | 2,68 | ||
Luft -20 °C Wasser 35 °C |
Thermische Leistung (kW) | 7,00 | 15,10 | |
COP | 2,51 | 2,42 | ||
Luft 2 °C Wasser 55°C |
Thermische Leistung (kW) | 12,70 | 23,10 | |
COP | 3,44 | 2,37 | ||
Kühlung | Luft 35 °C Wasser 7 °C |
Kühlleistung (kW) | 10,22 | 18,54 |
EER | 3,66 | 3,28 | ||
Luft 35 °C Wasser 18 °C |
Kühlleistung (kW) | 13,40 | 21,80 | |
EER | 5,04 | 4,75 |
Betriebsbedingungen | Kompressorlast | |||
---|---|---|---|---|
Med. | Max. | |||
Heizung | Luft 12 °C Wasser 35 °C |
Thermische Leistung (kW) | 20,40 | 33,50 |
COP | 5,38 | 4,33 | ||
Luft 7 °C Wasser 35 °C |
Thermische Leistung (kW) | 19,40 | 31,90 | |
COP | 5,13 | 4,14 | ||
Luft 2 °C Wasser 35 °C |
Thermische Leistung (kW) | 18,81 | 29,88 | |
COP | 4,43 | 3,56 | ||
Luft -7 °C Wasser 35 °C |
Thermische Leistung (kW) | 13,68 | 23,86 | |
COP | 3,26 | 2,96 | ||
Luft -15 °C Wasser 35 °C |
Thermische Leistung (kW) | 10,15 | 19,25 | |
COP | 2,67 | 2,42 | ||
Luft -20 °C Wasser 35 °C |
Thermische Leistung (kW) | 8,17 | 15,50 | |
COP | 2,50 | 2,27 | ||
Luft 2 °C Wasser 55°C |
Thermische Leistung (kW) | 15,88 | 28,80 | |
COP | 3,30 | 2,60 | ||
Kühlung | Luft 35 °C Wasser 7 °C |
Kühlleistung (kW) | 12,56 | 22,30 |
EER | 3,45 | 3,09 | ||
Luft 35 °C Wasser 18 °C |
Kühlleistung (kW) | 16,50 | 26,90 | |
EER | 4,74 | 4,48 |
Betriebsbedingungen | Kompressorlast | |||
---|---|---|---|---|
Med. | Max. | |||
Heizung | Luft 12 °C Wasser 35 °C |
Thermische Leistung (kW) | 23,60 | 33,50 |
COP | 5,26 | 4,25 | ||
Luft 7 °C Wasser 35 °C |
Thermische Leistung (kW) | 21,28 | 35,00 | |
COP | 5,07 | 4,10 | ||
Luft 2 °C Wasser 35 °C |
Thermische Leistung (kW) | 20,64 | 32,80 | |
COP | 4,29 | 3,52 | ||
Luft -7 °C Wasser 35 °C |
Thermische Leistung (kW) | 16,30 | 28,40 | |
COP | 3,23 | 2,93 | ||
Luft -15 °C Wasser 35 °C |
Thermische Leistung (kW) | 12,18 | 23,10 | |
COP | 2,64 | 2,39 | ||
Luft -20 °C Wasser 35 °C |
Thermische Leistung (kW) | 9,75 | 18,50 | |
COP | 2,37 | 2,15 | ||
Luft 2 °C Wasser 55°C |
Thermische Leistung (kW) | 17,42 | 31,60 | |
COP | 3,27 | 2,66 | ||
Kühlung | Luft 35 °C Wasser 7 °C |
Kühlleistung (kW) | 18,32 | 25,30 |
EER | 3,53 | 3,16 | ||
Luft 35 °C Wasser 18 °C |
Kühlleistung (kW) | 23,90 | 32,50 | |
EER | 4,85 | 4,62 |
Betriebsbedingungen | Kompressorlast | |||
---|---|---|---|---|
Med. | Max. | |||
Heizung | Luft 12 °C Wasser 35 °C |
Thermische Leistung (kW) | 23,60 | 33,50 |
COP | 5,52 | 4,70 | ||
Luft 7 °C Wasser 35 °C |
Thermische Leistung (kW) | 21,28 | 35,00 | |
COP | 5,32 | 4,37 | ||
Luft 2 °C Wasser 35 °C |
Thermische Leistung (kW) | 20,64 | 35,00 | |
COP | 4,50 | 3,67 | ||
Luft -7 °C Wasser 35 °C |
Thermische Leistung (kW) | 16,30 | 35,00 | |
COP | 3,39 | 2,80 | ||
Luft -15 °C Wasser 35 °C |
Thermische Leistung (kW) | 12,18 | 34,20 | |
COP | 2,77 | 2,43 | ||
Luft -20 °C Wasser 35 °C |
Thermische Leistung (kW) | 9,75 | 30,20 | |
COP | 2,49 | 2,25 | ||
Luft 2 °C Wasser 55°C |
Thermische Leistung (kW) | 17,42 | 35,00 | |
COP | 3,43 | 2,70 | ||
Kühlung | Luft 35 °C Wasser 7 °C |
Kühlleistung (kW) | 18,32 | 25,30 |
EER | 3,71 | 3,25 | ||
Luft 35 °C Wasser 18 °C |
Kühlleistung (kW) | 23,90 | 32,50 | |
EER | 5,09 | 4,76 |